STATE 241
Arc detected
Behaviors
Status code 241 is displayed immediately after codec 240. The inverter has detected a arc fault and disconnects from the grid for safety reasons.
Status Code Class 2
Class 2 status codes (state codes that start with a two, i.e., 2xx), may occur while feeding energy into the grid, but generally do not cause the process to be interrupted permanently.
The inverter temporarily disconnects automatically from the grid, the grid is then monitored as specified and the inverter attempts to resume feeding energy into the grid.
STATE 241 applies to:

Primo

Galvo

Symo
Solutions for this Error
Remedies
- Before an inverter can be reset following a detected electric arc, inspect the affected photovoltaic array for damage and faulty connectors.
- Once satisifeid witht the inspection, reset the status code by pressing the Enter key, or by following the steps outlined in the operations manual for your inverter.
Get Help with this Error:
The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider
DENVER RESIDENTS: Is your system located in the Denver, CO metro area? CONTACT US