Froniuis displaySTATE 307

STATE 307

DC input voltage is too low for grid power feed operation

Behaviors

Short interruption of grid power feed operation.

The inverter returns to the startup phase.

Status Code Class 3

Class 3 status codes (state codes that start with a three, i.e., 3xx), may occur while feeding energy into the grid, but generally do not cause the process to be interrupted permanently.

The inverter temporarily disconnects automatically from the grid, the grid is then monitored as specified and the inverter attempts to resume feeding energy into the grid.

STATE 307 applies to:

Primo

Primo

Galvo

Galvo

Symo

Symo

IG Plus

IG Plus

CL

CL

IG

IG

Solutions for this Error

Remedies

  • Wait for sufficient solar radiation

Additional Info

Status codes 306 (Power low) and 307 (DC low) appear naturally every morning and evening due to low solar irradiance. These codes may also appear when the array is covered in snow or during other low light conditions. These codes are typically not the result of a fault.

Get Help with this Error:

The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider