fronius logo
Froniuis displaySTATE 455

STATE 455

Reference power source for AC measurement is operating outside of tolerances

Behaviors

The inverter stops feeding power into the grid, the display

shows a critical error via a red Operating Status LED.

Status Code Class 4

Class 4 status codes (state codes that start with a four, i.e., 4xx), typically necessitate intervention by a Fronius-trained service technician.

STATE 455 applies to:

IG Plus

IG Plus

CL

CL

Solutions for this Error

Remedies

  • Check AC breakers and switches are in the ON position. Check mains AC voltage and frequency at the inverter clamps (Qualified persons only). This error should automatically clear once the grid is back within an acceptable range. If the grid is within operating parameters and this error persists, the device may have an internal failure.
  • If this issue persists, the next steps include inspecting internal inverter components and their cabling by a trained Fronius Service Provider to further diagnose this specific issue. Defective components or the device itself may need to be replaced.
  • Inverter Power Stage may need to be replaced

Get Help with this Error:

The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider

DENVER RESIDENTS: Is your system located in the Denver, CO metro area? CONTACT US

BACK