fronius logo
Froniuis displaySTATE 517

STATE 517

Power derating due to excessive temperature

Legacy equipment: Change of master has taken place.

Behaviors

A warning message is shown on the display when a power derating occurs

Legacy equipment: Transformer not connected, bridge short-circuit, or detection of intermediate circuit voltage damaged

Status Code Class 5

Class 5 status codes (state codes that start with a five, i.e., 5xx), do not generally interfere with feeding energy into the grid, but can cause restrictions. These status codes are displayed until they are acknowledged by pressing a key, however the inverter continues to operate normally in the background.

STATE 517 applies to:

Primo

Primo

Galvo

Galvo

Symo

Symo

IG Plus

IG Plus

CL

CL

IG

IG

Solutions for this Error

Remedies

  • Check inverter location, clearance of the ventilation ports. Clean air inlets and ensure exhaust ports have proper space.
  • If this issue persists, the next steps include inspecting internal inverter components and their cabling by a trained Fronius Service Provider to further diagnose this specific issue. Defective components or the device itself may need to be replaced.

Get Help with this Error:

The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider

DENVER RESIDENTS: Is your system located in the Denver, CO metro area? CONTACT US