STATE 225
No grid voltage detected
The inverter did not detect any AC voltage at its output terminals during grid evaluation.

ig
Expected Behaviors
- The inverter is displaying a STATE 225 message with a red or amber LED and is not currently operating. It is testing grid conditions every 5 minutes. Once the grid values return to within the permissible range, the inverter will automatically resume feeding energy into the grid.
State Class
A state class is a generalized description of errors, catagorized by the number the STATE code starts with.
These errors point to internal faults in the inverter itself, such as failed sensors, faulty current/voltage readings, or communication errors between internal modules. In many cases, these errors shut down the inverter and require intervention to resolve. They may not clear automatically and often point to hardware degradation or failure. Depending on the component affected, replacement or service by a Fronius trained technician is often needed, especially if the issue recurs..
- Ensure that all AC (grid) and DC (solar) disconnects and breakers are in the ON position.
- If this issue persists, it may be that the inverter has detected a fault within the external wiring and components, or an internal failure in the inverter. Further diagnosis, such as live circuit testing and internal inspection is required to troubleshoot further, which should only be performed by a trained Fronius Service Provider. Defective components or the inverter itself may require replacement.
Tips for Qualified Persons
The following procedures involve safety risks and potential for equipment damage. They are intended only for qualified personnel trained to identify and avoid the hazards that exist, and possess the appropriate PPE. These are general tips to aid professionals in troubleshooting, not instructions or directives to perform them.
We assume no liability for injury or damage resulting from their use.
- Measure the AC and DC voltages at the inverter input terminals. Verify that all cables and connectors are properly seated and secure. Visually inspect internal components for any signs of failure or damage.
- If all inspections and diagnostics have been completed and no resolution is found, it may be necessary to replace the faulty component, or the inverter itself. For advanced troubleshooting specific to your site, or to initiate a warranty claim, contact Fronius Technical Support at 1-877-Fro-nius (1-877-376-6487).

Fronius inverters in the U.S. typically come with a standard 10-year warranty. Starting in 2024, registering the inverter on the Fronius Solar.web website (the Fronius solar monitoring platform), extended the warranty by an additional 2 years, totaling 12 years of coverage, and updates the warranty start date to the actual installation date. Fronius has also offered warranty extensions of up to 20 years.
The inverter label, typically located on the bottom of the unit, lists the device serial number. To check if your inverter is still covered, call Fronius Technical Support at 1-877-Fro-nius (1-877-376-6487)


Founded in 1945 by Günter Fronius in Pettenbach, Austria, Fronius began as a repair shop for radios and electrical equipment. Recognizing the need for efficient battery charging, Günter developed a device to recharge car batteries, marking the company's first foray into energy solutions.
In the 1950s, Fronius expanded into welding technology, introducing the first welding transformer with magnet-yoke control in 1950. This innovation allowed for continuous adjustment of welding current, setting the stage for future advancements in welding systems. The company's commitment to innovation led to the development of the Transarc 500 in 1981, the world's first primary transistor-based inverter welding system, which significantly reduced power consumption. Fronius has since expanded into advanced welding automation recognized among key players in the industry, alongside firms like ABB, and Yaskawa Electric Corporation. Their current offerings include robotic welding systems, collaborative robots (cobots), and intelligent software solutions like Fronius Pathfinder, which provides functions for creating and simulating welding sequences. In 1992, Fronius ventured into photovoltaics, releasing its first photovoltaic inverter, the Fronius Sunrise, in 1995. This move marked the beginning of Fronius's Solar Energy division, which has since become a cornerstone of the company. Subsequent innovations include the IG inverter series in 2001, the SnapINverter technology in 2014, and the GEN24 Plus hybrid inverter in 2020, reflecting Fronius's ongoing commitment to advancing solar technology. Today, Fronius stands as one of the top-tier inverter manufacturers globally, often ranked alongside SMA (Germany), in terms of quality and market presence. While companies like Enphase dominate the U.S. microinverter space and SolarEdge leads in optimizer-based MLPE systems, Fronius remains a leading choice for high-efficiency string inverter systems, particularly in Europe, Australia, and commercial U.S. installations. Their inverters have robust build quality, excellent thermal performance (with active cooling), long warranties, and strong service support. With over 3.4 million inverters installed and more than 35 TWh of clean energy produced, Fronius competes head-to-head with larger players, maintaining a presence in premium residential and commercial markets globally.The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider in your area.
Fronius Technical Support can also be reached at 1-877-Fro-nius (1-877-376-6487)
DENVER RESIDENTS: Is your system located in the Denver, CO metro area? CONTACT US
Comment
Although this error can be caused by several different issues, it is quite common to receive this error as a result of a breaker or AC disconnect being open.