fronius logo
Froniuis displaySTATE 462

STATE 462

Error in DC feed-in monitoring routine

Behaviors

Inverter does not feed current into the grid.

Status Code Class 4

Class 4 status codes (state codes that start with a four, i.e., 4xx), typically necessitate intervention by a Fronius-trained service technician.

STATE 462 applies to:

Primo

Primo

Symo

Symo

Solutions for this Error

Remedies

  • Power Cycle the Inverter. To do so, both the DC and AC power sources must be disconnected to allow the device to discharge. Once the device has had time to discharge, turn on both the AC and DC power sources to the inverter.
  • Run latest firmware update
  • If this issue persists, the next steps include inspecting internal inverter components and their cabling by a trained Fronius Service Provider to further diagnose this specific issue. Defective components or the device itself may need to be replaced.

Get Help with this Error:

The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider

DENVER RESIDENTS: Is your system located in the Denver, CO metro area? CONTACT US

BACK