fronius logo
Froniuis displaySTATE 607

STATE 607

RCMU fault

Behaviors

Inverter does not feed energy into the grid.

Status Code Class 6

Class 6 status codes (state codes that start with a six, i.e., 6xx), may necessitate intervention by a Fronius-trained service engineer.

STATE 607 applies to:

Symo

Symo

Solutions for this Error

Remedies

  • Reset the status code by pressing the Enter key. The inverter resumes feeding energy into the grid
  • Check DC cables at the inverter and ensure DC disconnects are in the ON position. Measure DC voltage, polarity, and isolation at the inverter clamps (Qualified Techs only).

Get Help with this Error:

The best point of contact is your original installer
If the orginal installer is no longer available, contact a local Fronius Service Provider

DENVER RESIDENTS: Is your system located in the Denver, CO metro area? CONTACT US